Filter Element Separator Auto Drain Rental & Second Hand

 

 

DRY POINT AC

 

TECHNICAL DATA

Electrical connection
  Standard 115..230 Vac 50 / 60 Hz
  Option 24 Vdc  
Inlet temperature min./max. 2°C / 50°C
Ambient temperature min./max. 5°C / 50°C
Outlet PDP    
  Standard -40°C Option -20°C / -70°C
Other Parameters upon enquiry
       
All dryers are equipped with
CLEARPOINT® filters and a BEKOMAT® unit as standard.
Inlet filter : • Microfilter (0.01 pm)
Outlet filter : • Fine filter (1 pm)
       
Optional :
Second inlet filter • Fine filter (1 pm)

Spect.

 Model
 Performace [m3/h]
Connection
 A [mm]
 B [mm]
 C [mm]
 D [mm]
 E [mm]
 F [mm]
 Weight [kg]
AC0135
135
G1
1610
760
550
 340
 1430
800
190
AC0155
155
G1
 1800
760
 550
 340
 1620
800
220
AC0200
200
G1
 1500
760
 550
340
 1310
800
280
AC0280
280
G1
 1520
760
 550
 340
 1310
800
360
AC0380
380
G1 1/2
 1910
965
610
 405
 1585
900
440
AC0500
500
G1 1/2
 1785
965
610
 405
 1545
900
550
AC0630
630
G1 1/2
 1825
965
610
 405
 1575
900
640
AC0800
800
G2 1/2 
 1840
1330
875
 535
 1595
950
820
AC1000
1000
G2 1/2 
 1825
1330
875
 535
 1545
950
950
 AC1250
1250
G2 1/2 
 1850
1330
875
 535
 1555
950
1100
 AC1550
1550
G2 1/2 
 1920
1330
875
 535
 1585
950
1230
Standard operating pressure 10 bar, 16 bar optional. Higher nominal performance possible.
Please let us know your specific requirements.
Performance values related to 1 bar according to DIN ISO 7183, with inlet conditrions of 7 bar(g) and 35°C
Where the inlet conditions are different, the naminal performance value should be multiplied by the relevant correction factor.
 
Pressure/temperature correction factors:
Pressure [bar]
4
5
6
7
8
9
10
11
12
13
14
15
16
35 °C
0.63
0.75
0.88
1.00
1.13
1.25
1.38
1.50
1.63
1.75
1.88
2.00
2.13
40 °C
0.56
0.68
0.79
0.90
1.01
1.13
1.24
1.35
1.46
1.58
1.69
1.80
1.91
45 °C
0.51
0.61
0.71
0.81

0.91

1.01
1.11
1.22
1.32
1.42
1.52
1.62

1.72

50 °C
0.49

0.59

0.68
0.78
0.88
0.98
1.07
1.17
1.27
1.37
1.46
1.56
1.66
   
Regeneration air:              
The data listed in the table correspond to the regeneration-air percentage of the volumetric inlet flow.
PDP -20 °C [outlet]
18.0
15.4
12.9
11.3
10.0
9.1
8.2

7.6

7.0
6.5
6.0
5.6
5.3
PDP -40 °C [outlet]
24.0
20.5
17.1
14.8
13.3
12.1
10.9
10.0
9.2
8.6

8.0

7.4
7.1
PDP -70 °C [outlet]
26.7
22.8
19.0
16.7

14.8

13.4
12.1
11.2
10.3
9.6
8.9
8.4

7.9

                           
Subject to technical changes without prior notice; errors not excluded.